Measure the Number of Live and Dead Cells Simultaneously
The single-reagent-addition, homogeneous, fluorescent assay measures cell viability and cytotoxicity by detecting two distinct protease activities. The live-cell protease activity is restricted to intact viable cells and is measured using a fluorogenic, cell-permeant peptide substrate (GF-AFC Substrate). The substrate enters intact cells where it is cleaved to generate a fluorescent signal proportional to the number of living cells. This live-cell protease activity marker becomes inactive upon loss of membrane integrity and leakage into the surrounding culture medium. A second, cell-impermeant, fluorogenic peptide substrate (bis-AAF-R110 substrate) is used to measure dead-cell protease activity that has been released from cells that have lost membrane integrity.
The homogeneous, "add-mix-measure" protocol eliminates parallel plate processing and reduces cell culture costs, and the ratio of live:dead cells is independent of cell number and normalizes data. Data normalization for cell number makes results more comparable well-to-well, plate-to-plate, day-to-day.
Complementary live- and dead-cell measures with independent chemistries serve as internal controls for each other, and multiplexing capability with most Promega bioluminescent cell-based apoptosis or genetic reporter assays results in more data per well.
Notes
Cat # G9200 contains sufficient reagents for 100 assays at 100μl/assay in a 96-well format or 400 assays at 25μl/assay in a 384-well format. Cat # G9201 contains sufficient reagents for 500 assays at 100μl/assay in a 96-well format or 2,000 assays at 25μl/assay in a 384-well format. Cat # G9202 contains sufficient reagents for 1,000 assays at 100μl/assay in a 96-well format or 4,000 assays at 25μl/assay in a 384-well format.
Protocols
Complete Protocol
Specifications
Catalog Number:
Contenido
| Item | Part # | Presentación |
|---|---|---|
|
GF-AFC Substrate |
G608A | 1 × 10μl |
|
bis-AAF-R110 Substrate |
G609A | 1 × 10μl |
|
Assay Buffer |
G610A | 1 × 10ml |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
Store at –20°C.
Contenido
| Item | Part # | Presentación |
|---|---|---|
|
GF-AFC Substrate |
G608A | 5 × 10μl |
|
bis-AAF-R110 Substrate |
G609A | 5 × 10μl |
|
Assay Buffer |
G610A | 5 × 10ml |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
Store at –20°C.
Contenido
| Item | Part # | Presentación |
|---|---|---|
|
GF-AFC Substrate |
G608B | 2 × 50μl |
|
bis-AAF-R110 Substrate |
G609B | 2 × 50μl |
|
Assay Buffer |
G610B | 2 × 50ml |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
Store at –20°C.
Resources
No related resources available
Related Products
Productos Similares
MultiTox-Glo Multiplex Cytotoxicity Assay
Ensayo fluorescente y luminiscente que le permite medir el número relativo de células vivas y muertas en una población.
G9270, G9271, G9272
RealTime-Glo™ MT Cell Viability Assay
Método bioluminiscente que permite monitorizar la cinética de viabilidad de cultivos celulares durante 72 horas.
G9711, G9712, G9713
CellTox™ Green Cytotoxicity Assay
Mide los cambios en la integridad de la membrana. Monitoriza cinéticamente la citotoxicidad hasta 72 horas y además tiene capacidad multiplex.
G8741, G8742, G8743, G8731
CellTiter-Glo® 2.0 Cell Viability Assay
Versión actualizada del CellTiter-Glo® Cell Viability Assay con una estabilidad del reactivo mejorada. Cuantifica la proliferación celular basándose en la detección de ATP.
G9241, G9242, G9243
Usado con frecuencia junto con
CytoTox-Fluor™ Cytotoxicity Assay
Ensayo fluorescente homogéneo de adición de un solo reactivo, que le permite medir el número relativo de células muertas en poblaciones celulares.
G9260, G9261, G9262
CytoTox-Glo™ Cytotoxicity Assay
Ensayo de citotoxicidad basado en luminiscencia, de alta sensibilidad que mide el número relativo de células muertas.
G9290, G9291, G9292
GloMax® Discover System
Lector de microplacas de alto rendimiento para la detección de luminiscencia, fluorescencia y absorbancia.
GM3000