Rapid Pyruvate Detection from Diverse Samples
The Pyruvate-Glo™ Assay is a fast and sensitive method for detecting pyruvate in various biological samples, such as cultured cells, media and serum. Based on bioluminescent technology, the Pyruvate-Glo™ Assay can detect subtle changes in glycolysis and mitochondrial metabolism in just 75 minutes. Its streamlined sample preparation protocol involves acid treatment and neutralization directly in the assay wells, eliminating the need for cell collection, centrifugation and spin columns. The assay is adaptable to a 384-well format, facilitating quick analysis of many samples.
How the Pyruvate-Glo™ Assay Works
Pyruvate Oxidase catalyzes the reduction of pyruvate to acetyl phosphate, generating H2O2. In the presence of H2O2, the H2O2 Substrate is converted into luciferin. This reaction is detected by Ultra-Glo™ Recombinant Luciferase, which emits light proportionate to the amount of pyruvate in the sample.
Simple Assay Protocol Saves Time
Accurately Detect the Smallest Changes in Pyruvate
|
Sensitivity (S/B >5) |
1.56μM |
|
|
Limit of Detection (S/N >3) |
400nM |
|
|
Linear Range |
400nM to 50μM |
|
|
Maximum Assay Window (S/B) |
>150 |
|
Measure the Effect of Metabolic Inhibitors on Cellular Pyruvate Levels
The Pyruvate-Glo™ Assay can be used to monitor both intracellular and extracellular pyruvate in cell culture, including quickly assessing the metabolic effects of drug treatment.
Monitor metabolic effects of drug treatment with the Pyruvate-Glo™ Assay. K562 cells in suspension were incubated with DMSO (negative control), 10μM GSK2837808 (lactate dehydrogenase A inhibitor), 10μM 7ACC2 (monocarboxylate transporter 1-4 [MCT1-4] inhibitor) or 10μM UK5099 (mitochondrial pyruvate carrier inhibitor) for one to two hours. Following the incubations, half the volume was analyzed using the Pyruvate-Glo™ Assay (Panel A), and half the volume was removed for viability analysis using CellTiter-Glo® Luminescent Cell Viability Assay (Panel B). As expected, pyruvate levels increased approximately twofold after a 2-hour incubation with UK5099 and 7ACC2 compared to the DMSO control. There was no decrease in viability during treatment when compared to the DMSO control. All data represent an average of three replicates.
Do you want to learn more about our cellular energy metabolism tools and the innovative technology that powers these assays?
Protocols
Complete Protocol
Specifications
Catalog Number:
Contenido
| Item | Part # | Presentación |
|---|---|---|
H2O2 Substrate, 10mM |
G882A | 1 × 40μl |
Signal Enhancer Solution |
G883A | 1 × 100μl |
H2O2 Substrate Dilution Buffer |
G922A | 1 × 2ml |
Luciferin Detection Solution |
J135A | 1 × 5ml |
Neutralization Buffer |
J153A | 1 × 15ml |
0.6N HCl |
J402A | 1 × 15ml |
Pyruvate Oxidase (POX) |
J416A | 1 × 130μl |
Pyruvate, 10mM |
J417A | 1 × 50μl |
d-Cysteine, 100X |
V251A | 1 × 100μl |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
Contenido
| Item | Part # | Presentación |
|---|---|---|
H2O2 Substrate, 10mM |
G882B | 1 × 200μl |
Signal Enhancer Solution |
G883B | 1 × 500μl |
H2O2 Substrate Dilution Buffer |
G922B | 1 × 10ml |
Luciferin Detection Solution |
J135B | 1 × 50ml |
Neutralization Buffer |
J153A | 1 × 15ml |
0.6N HCl |
J402A | 1 × 15ml |
Pyruvate Oxidase (POX) |
J416B | 1 × 1300μl |
Pyruvate, 10mM |
J417A | 1 × 50μl |
d-Cysteine, 100X |
V251B | 1 × 500μl |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
Resources
Artículos
Posters
Related Products
Productos Similares
Glucose-Glo™ Assay
Detección de glucosa de forma sencilla en una amplia gama de muestras biológicas.
J6021, J6022
Lactate-Glo™ Assay
Ensayo bioluminiscente que detecta rápidamente el lactato a partir de diversos tipos de muestras.
J5021, J5022
Malate-Glo™ Assay
Método rápido y sensible para la detección de L-malato en diversas muestras biológicas.
JE9100, JE9200
Metabolite-Glo™ Detection System
Conjunto de herramientas de detección bioluminiscente de NAD(P)H para la detección de metabolitos en muestras biológicas.
J9030, J9040
Usado con frecuencia junto con
RealTime-Glo™ MT Cell Viability Assay
Método bioluminiscente que permite monitorizar la cinética de viabilidad de cultivos celulares durante 72 horas.
G9711, G9712, G9713
CellTiter-Fluor™ Cell Viability Assay
Ensayo de viabilidad celular fluorescente no lítico con capacidad multiplex.
G6080, G6081, G6082
CellTiter-Glo® 2.0 Cell Viability Assay
Versión actualizada del CellTiter-Glo® Cell Viability Assay con una estabilidad del reactivo mejorada. Cuantifica la proliferación celular basándose en la detección de ATP.
G9241, G9242, G9243
GloMax® Discover System
Lector de microplacas de alto rendimiento para la detección de luminiscencia, fluorescencia y absorbancia.
GM3000