pGL4 in vivo Imaging Vectors
Vectors That Are Highly Expressed in Mammalian Cell Lines for Animal Imaging Studies
- Two selectable marker options for creating stable mammalian cell lines
- Luciferase-expressing cells are used in animal models to study in vivo changes in cell physiology
- Firefly luciferase expression is driven by CMV promoter
Catalog Number:
Choose a selectable marker
Size
Catalog Number: E1310
Catalog Number: E1320
The pGL4.50[luc2/CMV/Hygro] and pGL4.51[luc2/CMV/Neo] Vectors are part of the pGL4 next generation reporter gene vectors optimized for expression in mammalian cells. Once these vectors are transfected into cultured cells, the luciferase-expressing cells can be used in animal imaging studies. The pGL4.50 and pGL4.51 Vectors have the synthetic firefly luciferase luc2 gene under the control of the strong constitutive CMV (cytomegalovirus) promoter. These vectors have demonstrated high expression levels in a variety of cell lines tested. The selectable marker options, either hygromycin or neomycin, can generate stable cell lines. Cell lines with constant expression of luciferase can be used in animal models to study in vivo changes in cell physiology.
Interested in other pGL4 Reporter Vectors? Browse them on the Reporter Vectors and Cell Lines web page.
pGL4.50[luc2/CMV/Hygro] Vector GenBank® Accession Number EU921840 and vector sequence text file.
pGL4.51[luc2/CMV/Neo] Vector GenBank® Accession Number EU921841 and vector sequence text file.
Specifications
Catalog Number:
Contenido
| Item | Part # | Presentación |
|---|---|---|
|
pGL4.50[luc2/CMV/Hygro] Vector |
E131A | 1 × 20μg |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If the researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide the researcher with a full refund.
Researchers may use this product for research use only, no commercial use is allowed. "Commercial use" means any and all uses of this product and derivatives by a party for money or other consideration and may include but is not limited to use in: (1) product manufacture; and (2) to provide a service, information or data; and/or resale of the product or its derivatives, whether or not such product or derivatives are resold for use in research. Researchers shall have no right to modify or otherwise create variations of the nucleotide sequence of the luciferase gene except that researchers may: (1) create fused gene sequences provided that the coding sequence of the resulting luciferase gene has no more than four deoxynucleotides missing at the affected terminus compared to the intact luciferase gene sequence, and (2) insert and remove nucleic acid sequences in splicing research predicated on the inactivation or reconstitution of the luminescence of the encoded luciferase. No other use or transfer of this product or derivatives is authorized without the prior express written consent of Promega. In addition, researchers must either: (1) use luminescent assay reagents purchased from Promega for all determinations of luminescence activity of this product and its derivatives; or (2) contact Promega to obtain a license for use of the product and its derivatives. Researchers may transfer derivatives to others for research use provided that at the time of transfer a copy of this label license is given to the recipients and recipients agree to be bound by the terms of this label license. With respect to any uses outside this label license, including any diagnostic, therapeutic or prophylactic uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH REGARDS TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 7,728,118.
Contenido
| Item | Part # | Presentación |
|---|---|---|
|
pGL4.51[luc2/CMV/Neo] Vector |
E132A | 1 × 20μg |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If the researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide the researcher with a full refund.
Researchers may use this product for research use only, no commercial use is allowed. "Commercial use" means any and all uses of this product and derivatives by a party for money or other consideration and may include but is not limited to use in: (1) product manufacture; and (2) to provide a service, information or data; and/or resale of the product or its derivatives, whether or not such product or derivatives are resold for use in research. Researchers shall have no right to modify or otherwise create variations of the nucleotide sequence of the luciferase gene except that researchers may: (1) create fused gene sequences provided that the coding sequence of the resulting luciferase gene has no more than four deoxynucleotides missing at the affected terminus compared to the intact luciferase gene sequence, and (2) insert and remove nucleic acid sequences in splicing research predicated on the inactivation or reconstitution of the luminescence of the encoded luciferase. No other use or transfer of this product or derivatives is authorized without the prior express written consent of Promega. In addition, researchers must either: (1) use luminescent assay reagents purchased from Promega for all determinations of luminescence activity of this product and its derivatives; or (2) contact Promega to obtain a license for use of the product and its derivatives. Researchers may transfer derivatives to others for research use provided that at the time of transfer a copy of this label license is given to the recipients and recipients agree to be bound by the terms of this label license. With respect to any uses outside this label license, including any diagnostic, therapeutic or prophylactic uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH REGARDS TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 7,728,118.
Resources
Artículos
Related Products
Productos Similares
Promoter-Driven Control Firefly Luciferase Vectors
Tres vectores reporteros pGL4 con un promotor (SV40, PGK o TK) que se utilizan como control reportero para ensayos de doble luciferasa.
E6681, E5011, E5061
Promoter-Driven Control NanoLuc® Luciferase Vectors
Tres vectores reporteros NanoLuc® con promotor CMV, PGK o TK. Co-transfección con vectores de luciferasa firefly para la normalización en ensayos de doble reportero.
N1441, N1501, N1091
Control NanoLuc® Reporter Vector with Hygromycin Selection
Vector pNL3.2.CMV que se utiliza como control negativo para medir los cambios en los niveles de expresión de la NanoLuc® Luciferase (NlucP).
N1411
pmirGLO Dual-Luciferase miRNA Target Expression Vector
Permite evaluar la actividad de los microARN (miARN) insertando sitios diana adyacentes al gen de la luciferasa firefly. Normaliza con Renilla luciferasa.
E1330
Usado con frecuencia junto con
ViviRen™ In Vivo Renilla Luciferase Substrate
Sustrato de ingeniería genética a base de celenterazina modificado para minimizar la degradación del sustrato y la autoluminiscencia en estudios de imaging animal.
P1231, P1232
ONE-Glo™ EX Luciferase Assay System
Ensayo ONE-Glo™ Assay mejorado. Mayor sensibilidad, luminiscencia de larga duración, más opciones de almacenamiento.
E8110, E8120, E8130, E8150
Renilla-Glo® Luciferase Assay System
Ensayo sencillo "add and read" para reporteros de Renilla luciferasa. Optimizado para procesamiento continuo y por lotes.
E2710, E2720, E2750
Steady-Glo® Luciferase Assay System
Ensayo reportero sensible con luminiscencia de larga duración para el procesamiento por lotes en placas multipocillo.
E2510, E2520, E2550
Dual-Luciferase® Reporter Assay System
Detección consecutiva de las actividades luciferasa firefly y Renilla en una sola muestra. Requiere luminómetro con 2 inyectores.
E1910, E1960, E1980
Dual-Glo® Luciferase Assay System
Detección de forma consecutiva de las actividades luciferasa firefly y Renilla en una sola muestra. Vida media de la señal de dos horas. No requiere inyectores.
E2920, E2940, E2980