Bright-Glo™ Luciferase Assay System
Sensitive Reporter Assay for Continuous Processing on Robotic Systems
- Sensitive, bright signal with 30-minute half-life
- No need to remove culture medium or wash cells prior to adding assay reagent
- Less sensitive to mixing conditions, sample evaporation and pipetting errors
Catalog Number:
Size
Catalog Number: E2610
Catalog Number: E2620
Catalog Number: E2650
Not sure if this assay is right for you?
We have a product guide to help you choose the right Luciferase Reporter Assay.
Improved Precision and Reproducibility for High-Throughput Reporter Assays
High-throughput quantitation of firefly (Photinus pyralis) luciferase expression in mammalian cells requires highly sensitive reagents that can adapt to continuous-process robotic systems. Bright-Glo™ Luciferase Assay System is designed specifically to meet the needs of continuous-process systems by providing robust, homogeneous assay chemistry that achieves high assay sensitivity and approximately 30-minute signal half-life without prior sample processing. The assay is also less sensitive to mixing conditions, sample evaporation and pipetting errors. These attributes also benefit those who are using fewer samples but still require high sensitivity and ease of use.
Assay Advantages
- No sample preprocessing. With the Bright-Glo Assay, there is no need to remove culture medium or wash cells prior to adding assay reagent. Grow and assay cells directly in the same multiwell plate.
- High Sensitivity. Up to tenfold more sensitive than other homogenous luciferase assay reagents.
- Convenient and Easy to Use. Simply mix buffer with lyophilized substrate and add to cells in culture medium; no need to thaw or measure before use.
Learn more about custom options for this product at: www.promega.com/custom/
Contact Promega for information on bulk purchases.
Protocols
Specifications
Catalog Number:
Contenido
| Item | Part # | Presentación |
|---|---|---|
|
Bright-Glo™ Luciferase Assay Substrate |
E263A | 1 × 1 vial |
|
Bright-Glo™ Luciferase Assay Buffer |
E264A | 1 × 10ml |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
See Protocol for detailed storage recommendations.
Contenido
| Item | Part # | Presentación |
|---|---|---|
|
Bright-Glo™ Luciferase Assay Substrate |
E263B | 1 × 1 vial |
|
Bright-Glo™ Luciferase Assay Buffer |
E264B | 1 × 100ml |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
See Protocol for detailed storage recommendations.
Contenido
| Item | Part # | Presentación |
|---|---|---|
|
Bright-Glo™ Luciferase Assay Substrate |
E263B | 10 × 1 vial |
|
Bright-Glo™ Luciferase Assay Buffer |
E264B | 10 × 100ml |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
See Protocol for detailed storage recommendations.
Resources
No related resources available
Related Products
Productos Similares
Nano-Glo® Luciferase Assay System
Ensayo "add-mix-measure" de NanoLuc® Luciferase con >2 horas de vida media en la mayoría de las aplicaciones.
N1110, N1120, N1130, N1150
Nano-Glo® Dual-Luciferase Reporter Assay System
Detección ultrasensible de la actividad luciferasa firefly y NanoLuc® en una sola muestra.
N1610, N1620, N1630, N1650, N1521, N1531, N1541, N1551
ONE-Glo™ EX Luciferase Assay System
Ensayo ONE-Glo™ Assay mejorado. Mayor sensibilidad, luminiscencia de larga duración, más opciones de almacenamiento.
E8110, E8120, E8130, E8150
Steady-Glo® Luciferase Assay System
Ensayo reportero sensible con luminiscencia de larga duración para el procesamiento por lotes en placas multipocillo.
E2510, E2520, E2550
Usado con frecuencia junto con
GloMax® Discover System
Lector de microplacas de alto rendimiento para la detección de luminiscencia, fluorescencia y absorbancia.
GM3000
GloMax® Navigator System
Luminómetro para microplacas.
GM2000, GM2010
FuGENE® 6 Transfection Reagent
Rendimiento probado y robusto. La mejor opción para un uso diario con líneas celulares habituales.
E2691, E2692, E2693
ViaFect™ Transfection Reagent
Transfección de alta eficacia y baja toxicidad de muchos tipos celulares, incluyendo las células iPS.
E4981, E4982