ONE-Glo™ EX Luciferase Assay System
Highly Sensitive Assay with Long-Lived Luminescence
- Bright, stable signal that can be measured for hours
- Stable reagent can be stored at room temperature or 4°C
- Reduced sensitivity to culture media, phenol red and luciferase inhibitors
Catalog Number:
Size
Catalog Number: E8110
Catalog Number: E8120
Catalog Number: E8130
Catalog Number: E8150
Not sure if this assay is right for you?
We have a product guide to help you choose the right Luciferase Reporter Assay.
Bright, Stable, Firefly Luciferase Assay with Improved Handling and Performance
High- or ultrahigh-throughput quantitation of firefly luciferase expression in mammalian cells is commonly performed by measuring luminescence from 96-, 384- or 1,536-well plates. The ONE-Glo™ EX Luciferase Assay System provides both the high sensitivity and long-lived luminescence required to batch-process multiple plates in these assay formats.
Assay Advantages
- Increased stability of reconstituted reagent at room temperature or 4°C simplifies repeat use over long experiments and reduces waste; no odor-causing compounds in the reagent.
- Bright and stable signal that can be measured for hours enables more consistent luminescence readings; ideal for screening and batch processing.
- The homogenous firefly luciferase detection reagent can be used in both single- or dual-luciferase assays; compatible with any plate size up to 1,536-well format.
- Fewer Unwanted Effects from Sample Components. Reduced sensitivity to culture media, phenol red and luciferase inhibitors compared to other luciferase assays.
Stable Luminescence Signal Supports Batch Processing
The ONE-Glo™ EX Assay offers many of the same benefits of the ONE-Glo™ Assay, including use of 5´-fluoroluciferin substrate and an add-mix-read, or homogeneous, protocol. However, the ONE-Glo™ EX Reagent uses a new assay chemistry to increase the stability of both the luminescence signal and the reconstituted reagent. The approximately 2-hour signal half-life provides greater flexibility in assay design.
The example data shown here illustrate how the ONE-Glo™ EX signal persisted over 2 hours. In this experiment, 100µl purified firefly luciferase (13.8ng/ml) was combined in a 96-well plate with 100µl of Bright-Glo™, ONE-Glo™, ONE-Glo™ EX, Dual-Glo® Luciferase or Steady-Glo® Reagents. Luminescence was measured periodically over 2 hours, n = 8.
More Storage Options for Reconstituted Reagent
The reconstituted ONE-Glo™ EX reagent can be stored at room temperature for longer periods, so there is less variability in reagent performance during long experiments or screens and less sample waste. ONE-Glo™ EX Reagent is the firefly luciferase detection reagent used in the Nano-Glo® Dual-Luciferase® Reporter (NanoDLR™) Assay System; the same reagent is used for single- or dual-luciferase assays.
This data shows the stability of the ONE-Glo™ EX Reagent over 20 days when stored at 22°C or 7°C.
Protocols
Specifications
Catalog Number:
Contenido
| Item | Part # | Presentación |
|---|---|---|
ONE-Glo™ EX Luciferase Assay Buffer |
E632A | 1 × 10ml |
ONE-Glo™ EX Luciferase Assay Substrate |
E633A | 1 × 1 vial |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
See Protocol for detailed storage recommendations.
U.S. Pat. No. 9,487,814, European Pat. No. 2959010 and other patents and patents pending.
Contenido
| Item | Part # | Presentación |
|---|---|---|
ONE-Glo™ EX Luciferase Assay Buffer |
E632B | 1 × 100ml |
ONE-Glo™ EX Luciferase Assay Substrate |
E633B | 1 × 1 vial |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
See Protocol for detailed storage recommendations.
U.S. Pat. No. 9,487,814, European Pat. No. 2959010 and other patents and patents pending.
Contenido
| Item | Part # | Presentación |
|---|---|---|
ONE-Glo™ EX Luciferase Assay Buffer |
E632A | 10 × 10ml |
ONE-Glo™ EX Luciferase Assay Substrate |
E633A | 10 × 1 vial |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
See Protocol for detailed storage recommendations.
U.S. Pat. No. 9,487,814, European Pat. No. 2959010 and other patents and patents pending.
Contenido
| Item | Part # | Presentación |
|---|---|---|
ONE-Glo™ EX Luciferase Assay Buffer |
E632B | 10 × 100ml |
ONE-Glo™ EX Luciferase Assay Substrate |
E633B | 10 × 1 vial |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
See Protocol for detailed storage recommendations.
U.S. Pat. No. 9,487,814, European Pat. No. 2959010 and other patents and patents pending.
Resources
Related Products
Productos Similares
Nano-Glo® Dual-Luciferase Reporter Assay System
Detección ultrasensible de la actividad luciferasa firefly y NanoLuc® en una sola muestra.
N1610, N1620, N1630, N1650, N1521, N1531, N1541, N1551
ONE-Glo™ + Tox Luciferase Reporter and Cell Viability Assay
Detección sensible de la actividad reportera y de la viabilidad celular en un solo pocillo.
E7110, E7120
Dual-Glo® Luciferase Assay System
Detección de forma consecutiva de las actividades luciferasa firefly y Renilla en una sola muestra. Vida media de la señal de dos horas. No requiere inyectores.
E2920, E2940, E2980
Nano-Glo® Luciferase Assay System
Ensayo "add-mix-measure" de NanoLuc® Luciferase con >2 horas de vida media en la mayoría de las aplicaciones.
N1110, N1120, N1130, N1150
Usado con frecuencia junto con
CellTiter-Glo® 2.0 Cell Viability Assay
Versión actualizada del CellTiter-Glo® Cell Viability Assay con una estabilidad del reactivo mejorada. Cuantifica la proliferación celular basándose en la detección de ATP.
G9241, G9242, G9243
ViaFect™ Transfection Reagent
Transfección de alta eficacia y baja toxicidad de muchos tipos celulares, incluyendo las células iPS.
E4981, E4982
FuGENE® 6 Transfection Reagent
Rendimiento probado y robusto. La mejor opción para un uso diario con líneas celulares habituales.
E2691, E2692, E2693
GloMax® Discover System
Lector de microplacas de alto rendimiento para la detección de luminiscencia, fluorescencia y absorbancia.
GM3000